A magnetic pull test is a reliable and widely used method throughout the industry for determining the strength of a magnet. Strength is important, as it determines how effective the magnet will be in its given application.

OVERVIEW

Why test Magnetic Strength?

A magnetic pull test is a reliable and widely used method throughout the industry for determining the strength of a magnet. Strength is important, as it determines how effective the magnet will be in its given application. A magnetic pull test can be used in comparing two magnetic devices that look very similar on the outside, but may have different magnetic circuitry or magnet material on the inside, resulting in a more, or less, effective magnet. Magnetic pull strength testing can be performed on magnets with round or flat surfaces and on either permanent or electromagnetic circuits.

Principle

Pull strength is determined by using a calibrated scale and a ferrous test piece. A ferrous metal plate is used to test plate magnets and conveying rail, while a ferrous metal sphere is used to test magnetic tubes. The ferrous object is attached to the snap swivel hook on the scale and drawn away 90 degrees from the magnet until it is released. The pull strength, or pounds of pull it takes to release the test piece from the magnet, indicates the strength of the magnet.

It is important that each pull test be conducted with consistency to ensure that an accurate reading is achieved and we recommend that you use the average of several pull tests to determine your reading.

Handheld Linear Mechanical Scale Specifications

  • Accuracy: +/- 1 Graduation
  • Avoirdupois and Metric Graduations
  • Brass construction with precision steel springs
  • Lightweight with a swivel safety hook
  • Maximum reading pointer
  • Zero/Tare knob standard
  • Maximum Overload: 125% of capacity
  • Tare Capacity: 10% full scale capacity
  • Operating Temperature: 45° - 100°F (7° - 38°C)
  • Weight: 32 oz (907 g)

Handheld Digital Force Gauge Specifications

  • Accuracy: +/- 0.5% of full scale
  • Power: 4 x 1.5v AA Batteries included
  • LCD Display
  • Lightweight Plastic Housing
  • Tension and compression measurement
  • Data output: RS-232
  • Auto Power Off after 5 minutes of inactivity
  • Overload: 120% of capacity - Overload Warning
  • Weight: 8.8 oz (249 g)
  • Operating temperature: 50° - 95°F (10° - 35°C)

Magnetic Pull Test Kit Products

Measurements in inches and lbs
Magnetic Pull Test Kit variants and specifications
SKUDescriptionIn Stock
Thumbnail of SKU PTK2000Switch to product variant SKU PTK2000Magnetic Pull Test Kit with Standard Pull Scale
Thumbnail of SKU PTK3002Switch to product variant SKU PTK3002Magnetic Pull Test Kit with Digital Pull Scale
Thumbnail of SKU PTK3002NISTSwitch to product variant SKU PTK3002NISTMagnetic Pull Test Kit with Digital Pull Scale - NIST Traceable
Thumbnail of SKU PTKDGT02Switch to product variant SKU PTKDGT02Digital Pull Scale to be used with Pull Test Kit
Thumbnail of SKU PTKDGT02NISTSwitch to product variant SKU PTKDGT02NISTDigital Pull Scale - NIST traceable - to be used with Pull Test Kit

Pull Test Kit Contents

Pull Test Kit Contents
CONTENTSWHERE TO USEPTK2000PTK3002PTK3002NISTPTKDGT02PTKDGT02NIST
1 pc. Handheld Digital Force Gauge0-44 lbs. Digital pull scale (Small Ball on Rare Earth)XX
1 pc. Handheld Digital Force Gauge - NIST Traceable0-44 lbs. Digital pull scale (Small Ball on Rare Earth)XX
1 Set of four Spacers (1/8" thick, 1" wide, 4" long stainless steel bar stock pieces)Use for testing air gap in 1/8" increments on magnetic tubes, plates and rail.XXX
1 pc. Ball* on ring, 1" diameterOn surface of: Ceramic, tubes, pipe, plates and bullet magnets.XXX
1 pc. Ball* on ring, 1/2" diameterOn surface of: Ceramic or Rare Earth (see above).XXX
1 pc. Ball* on ring, 1/4" diameterOn surface of Rare Earth round products (tubes, pulleys, etc.).XXX
1 pc. Round Test Plate (16 ga. x 3" dia.)Ceramic or electromagnetic flat surfaces with Airgap.XXX
1 pc. Polarity TesterUsed to determine if magnets are properly aligned. Magnetic rail should be N to N and S to S. Magnetic tubes should alternate NSNS.XXX
1 pc. Magnetic Viewing Film (4" x 4" sheet)Used to show gap between magnets, either air or pole pieces.XXX
1 pc. General 6" ruleUsed to measure magnet thickness and application areas.XXX

*Test balls are 1010-1020 (low) carbon steel. Hardness: Very Hard Rockwell C60. Tolerance: +/- 0.005". Meets ASTM A29 Standard.

Downloads

Manual

Pull Test Kit - PTK2000, PTK3002 & PTKDGT02

Download
Thumbnail of document Pull Test Kit - PTK2000, PTK3002 & PTKDGT02
Contact Us

I'd like to speak to a magnetics expert

Have questions you’d like to speak to an IMI team member about? Fill out the contact form with the information you have, and a member of our sales team will be in touch soon. We can’t wait to chat.

By submitting this form, I agree to Industrial Magnetics, Inc.'s Privacy Policy and Terms of Use.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.