Why Should I Use A Lift Magnet Certification Service?
Visual checks aren't enough for lift magnets! Internal damage can cause failure. Our Lift Magnet Testing and Certification Service performs both a thorough visual inspection and functional testing of your magnetic lifting products using testing techniques and equipment that meet or exceed the ASME B30.20 Standards for Below-the-Hook Magnetic Lifting Devices. These performance tests are often referred to as breakaway tests.
Proper breakaway testing of a lift magnet will determine the maximum lift capacity of that magnet under ideal conditions. The outcome of the test allows the operator/owner of the lift to determine if the magnet meets the rated Working Load Limit (WLL) or lift capacity as designed by the manufacturer. After testing, We provide documentation of the testing and a certificate of conformance if the magnet meets the manufacturer's labeled rating. Damaged label replacement is also included for Industrial Magnetics Inc. labeled Lift Magnets.
Common Factors For Lift Magnet Loss Of Performance Or Failure:
- Blunt force impact such as dropping, or banging on, the magnet can cause fractures in the magnet
- If the magnet is exposed to temperatures above its’ capabilities it will lose magnetism
- Exposure to electrical fields, like generators or welding ground circuits, will result in loss of magnetism.
- External factors that influence a lift magnet’s performance are nicks, scratches, gouges, rust, etc. to the contact surface of the lifter.
Breakaway testing will prove the magnet is performing at the intended Working Load Limit (WLL).